O Ajuste Automático da Fração Inspirada de Oxigénio (FiO2) e o Tempo em Normoxémia em Recém-Nascidos Prematuros

Autores

  • Gustavo Rocha Department of Neonatology. Centro Hospitalar e Universitário de São João. Porto. Portugal. https://orcid.org/0000-0003-3057-6054
  • Paulo Soares Department of Neonatology. Centro Hospitalar e Universitário de São João. Porto. Portugal.
  • Filipa Flor-de-Lima Department of Neonatology. Centro Hospitalar e Universitário de São João. Porto. Portugal; Department of Obstetrics, Gynecology, and Pediatrics. Faculty of Medicine. Universidade do Porto. Porto. Portugal.
  • Rita Amaral Department of Community Medicine, Information and Health Decision Sciences (MEDCIS). Faculty of Medicine. Universidade do Porto. Porto. Portugal; CINTESIS@RISE - Health Research Network. Faculty of Medicine. Universidade do Porto. Porto. Portugal; Department of Women’s and Children’s Health. Uppsala University. Uppsala. Sweeden.

DOI:

https://doi.org/10.20344/amp.22397

Palavras-chave:

Hiperoxemia, Hipoxemia, Oxigenoterapia, Recém-Nascido Prematuro

Resumo

Introdução: O desafio de manter a normoxemia em recém-nascidos pré-termo submetidos a suporte respiratório e terapia com oxigénio levou ao desenvolvimento de sistemas de controlo automático em circuito fechado para a FiO2. O objetivo deste estudo foi avaliar a eficácia destes sistemas na manutenção da SpO2 dentro de uma faixa alvo (90% - 94%) em recém-nascidos pré-termo sob oxigénio suplementar.
Métodos: Conduzimos um estudo prospetivo unicêntrico ao longo de um período de três anos (2020 - 2023) incluindo recém-nascidos pré-termo com idade gestacional < 33 semanas que receberam oxigénio suplementar nas primeiras 24 horas de vida e suporte respiratório invasivo ou não invasivo. O dispositivo de controlo automático em circuito fechado da FiO2 utilizado foi o Controlo Inteligente Preditivo da Oxigenação nos ventiladores Fabian®. Foram aleatorizados e comparados dois grupos, um que beneficiou do controlo automático mais manual da FiO2 e outro que recebeu apenas controlo manual de rotina. A análise de regressão (linear ou de Poisson) uni- e multivariada avaliou a associação entre a utilização do controlo automático em circuito fechado da FiO2 e os parâmetros de ajustes manuais, hipoxemia, hiperoxemia e normoxemia.
Resultados: Foram incluídos 89 pacientes, 45 receberam controlo automático em circuito fechado da FiO2 e 44 receberam controlo manual de rotina. O primeiro grupo necessitou de menos ajustes manuais da FiO2, apresentou menor número de episódios de hipoxemia e hiperoxemia (p < 0,002), e passou mais tempo com a SpO2 dentro da faixa alvo (p < 0,001), em comparação com o segundo grupo. Após ajuste para variáveis de confundimento, o tempo total em normoxemia demonstrou uma associação significativa com o controlo automático em circuito fechado da FiO2 (β = 81,5; IC95%: 47,9 - 115,2; p < 0,001).
Conclusão: O uso do controlo automático em circuito fechado da FiO2 parece ser viável e estava associado a um menor número de episódios de hipóxia e hiperóxia, mantendo assim a SpO2 dentro dos limites normais por períodos mais longos. Além disso, associou-se a uma redução do número de intervenções manuais.

Downloads

Não há dados estatísticos.

Referências

Carlo WA, Finer NN, Walsh MC, Rich W, Gantz MG, Laptook AR, et al; SUPPORT study group of the eunice kennedy shriver nichd neonatal research network. Target ranges of oxygen saturation in extremely preterm infants. N Engl J Med. 2010;362:1959-69.

Stenson BJ, Tarnow-Mordi WO, Darlow BA, Simes J, Juszczak E, Askie L, et al; BOOST II United Kingdom Collaborative Group; BOOST II Australia Collaborative Group; BOOST II New Zealand Collaborative Group. Oxygen saturation and outcomes in preterm infants. N Engl J Med. 2013;368:2094-104.

Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Te Pas A, et al. European consensus guidelines on the management of respiratory distress syndrome - 2019 update. Neonatology. 2019;115:432-50.

Bolivar JM, Gerhardt T, Gonzalez A, Hummler H, Claure N, Everett R, et al. Mechanisms for episodes of hypoxemia in preterm infants undergoing mechanical ventilation. J Pediatr. 1995;127:767-73.

Hütten MC, Goos TG, Ophelders D, Nikiforou M, Kuypers E, Willems M, et al. Fully automated predictive intelligent control of oxygenation (PRICO) in resuscitation and ventilation of preterm lambs. Pediatr Res. 2015;78:657-63.

Dijkman KP, Mohns T, Dieleman JP, van Pul C, Goos TG, Reiss IK, et al. Predictive intelligent control of oxygenation (PRICO) in preterm infants on high flow nasal cannula support: a randomised cross-over study. Arch Dis Child Fetal Neonatal E. 2021;106:621-6.

Rocha G, de Lima FF, Machado AP, Guimarães H; Collaborators of the hypertensive disorders of pregnancy study group. Preeclampsia predicts higher incidence of bronchopulmonary dysplasia. J Perinatol. 2018;38:1165-73.

Madar J, Roehr CC, Ainsworth S, Ersdal H, Morley C, Rüdiger M, et al. European resuscitation council guidelines 2021: newborn resuscitation and support of transition of infants at birth. Resuscitation. 2021;161:291-326.

Dargaville PA, Marshall AP, McLeod L, Salverda HH, Te Pas AB, Gale TJ. Automation of oxygen titration in preterm infants: current evidence and future challenges. Early Hum Dev. 2021;162:105462.

Hagadorn JI, Furey AM, Nghiem TH, Schmid CH, Phelps DL, Pillers DA, et al; AVIOx Study Group. Achieved versus intended pulse oximeter saturation in infants born less than 28 weeks’ gestation: the AVIOx study. Pediatrics. 2006;118:1574-82.

Dani C. Automated control of inspired oxygen (FiO2 ) in preterm infants: literature review. Pediatr Pulmonol. 2019;54:358-63.

Sturrock S, Ambulkar H, Williams EE, Sweeney S, Bednarczuk NF, Dassios T, et al. A randomised crossover trial of closed loop automated oxygen control in preterm, ventilated infants. Acta Paediatr. 2021;110:833-7.

Sturrock S, Williams E, Dassios T, Greenough A. Closed loop automated oxygen control in neonates-a review. Acta Paediatr. 2020;109:914-22.

Abdo M, Hanbal A, Asla MM, Ishqair A, Alfar M, Elnaiem W, et al. Automated versus manual oxygen control in preterm infants receiving respiratory support: a systematic review and meta-analysis. J Matern Fetal Neonatal Med. 2022;35:6069-76.

Kaltsogianni O, Dassios T, Belbal R, Greenough A. Survey of closedloop automated oxygen control systems in neonatal intensive care units. Acta Paediatr. 2022;111:1002-3.

Salverda HH, Oldenburger NN, Rijken M, Tan RR, Pas AB, van Klink JM. Automated oxygen control for very preterm infants and neurodevelopmental outcome at 2 years-a retrospective cohort study. Eur J Pediatr. 2023;182:1593-9.

Maiwald CA, Niemarkt HJ, Poets CF, Urschitz MS, König J, Hummler H, et al. Effects of closed-loop automatic control of the inspiratory fraction of oxygen (FiO2-C) on outcome of extremely preterm infants - study protocol of a randomized controlled parallel group multicenter trial for safety and efficacy. BMC Pediatr. 2019;19:363.

Dijkman KP, Goos TG, Dieleman JP, Mohns T, van Pul C, Andriessen P, et al. Predictive intelligent control of oxygenation in preterm infants: a two-center feasibility study. Neonatology. 2023;120:235-41.

van Kaam AH, Hummler HD, Wilinska M, Swietlinski J, Lal MK, te Pas AB, et al. Automated versus manual oxygen control with different saturation targets and modes of respiratory support in preterm infants. J Pediatr. 2015;167:545-50.e1-2.

Martin RJ, Wang K, Köroğlu O, Di Fiore J, Kc P. Intermittent hypoxic episodes in preterm infants: do they matter? Neonatology. 2011;100:303-10.

Deuber C, Terhaar M. Hyperoxia in very preterm infants: a systematic review of the literature. J Perinat Neonatal Nurs. 2011;25:268-74.

Publicado

2025-04-01

Como Citar

1.
Rocha G, Soares P, Flor-de-Lima F, Amaral R. O Ajuste Automático da Fração Inspirada de Oxigénio (FiO2) e o Tempo em Normoxémia em Recém-Nascidos Prematuros. Acta Med Port [Internet]. 1 de Abril de 2025 [citado 11 de Dezembro de 2025];38(4):208-16. Disponível em: https://actamedicaportuguesa.com/revista/index.php/amp/article/view/22397

Edição

Secção

Original